HiperMAX Commissioning Job Sheet

 

Job Sheet

Base Station

Information

Notes

BS location

 

 

ATCA rack identity

 

 

GPS timing reference

 

Whether the system is required to be locked to a GPS timing reference.

SDR Blade (per Blade)

SDR Blade Slot x

 

This needs to be provided for each SDR Blade. See Note 1

Primary Master, Secondary Master or a Slave

 

Whether the SDR is to be a Primary Master, Secondary Master or a Slave. This information will be mapped to the ATCA rack slot number by this procedure.

GPS management

 

Whether the Primary Master blade or the Secondary Master blade manages the GPS module.

BSID

 

A BSID is required for each SDR Blade. This should be in a format xxxxxx:xxxxxx where x is a decimal digit.

SCRT ID to Obsai port ID Mapping

 

The mapping of SCRT ID to Obsai port ID on the SDR blade.

Network configuration

 

 

Network configuration information for the SDR blade. This shall include the following information for the front panel and the backplane.

Traffic Port

 

Defines whether traffic is via the front panel of the "SDR blade", "Primary Backplane" or "Secondary Backplane".

IP Address  

 

Should only be set if  "Management IP Mode" is set to "Static IP Address"  See below for "Management IP Mode" parameter.

Netmask

 

Should only be set if  "Management IP Mode" is set to "Static IP Address"  See below for "Management IP Mode" parameter.

Default Gateway

 

Should only be set if  "Management IP Mode" is set to "Static IP Address"  See below for "Management IP Mode" parameter.

Management VLAN

 

Specified as either "Untagged" or "Tagged"

Management VLAN Tag

 

Should only be set if "Management VLAN" is set to "Tagged"

Management IP Mode

 

Specified as "Static IP Address" or "Obtain IP Address via DHCP"

Ethernet Mode

 

Specified as "Autonegotiate" or  "Fixed"  

Ethernet Rate

 

Need only be configured if "Ethernet Mode" is set to "Fixed". Specified as "10M" or "100M".

Ethernet Duplex

 

Need only be configured if "Ethernet Mode" is set to "Fixed". Specified as "Full" or "Half"

SNMP Configuration

This will allow events from the BS to arrive at the specified Netspan server. This will include the following information:

Read Only Community

 

This should be specified to the same value as in Netspan's Discovery Parameters. (Found under "Server" on Netspan's left hand panel).

Read Write Community

 

This should be specified to the same value as in Netspan's Discovery Parameters. (Found under "Server" on Netspan's left hand panel).

SNMP Port Number :

 

This should be specified to the same value as in Netspan's Discovery Parameters. (Found under "Server" on Netspan's left hand panel).

IP Address

 

This specifies Netspan's IP address (Found under "Server Global Configuration" which is under "Server" on Netspan's left hand panel).

Community

 

Normally specified to the same value as for "Read Only Community"

Port Number

 

 Normally specified to a value of 9023.

NTP Configuration

 

This specifies a list of NTP servers.

Switch (per Switch)

Blade Traffic /Management

Traffic

Management

Separate Ethernet management and traffic ports or an Ethernet port with combined management and user traffic.

Switch Management

 

In Band

Out of Band

Switch Management in Network Ethernet (in band) or in separate Management Ethernet (out of band).

 

 

 

IP addresses for management

Shelf Manager

Shelf Address

 

Up to 30 character string used to identify this shelf.

Password

 

minimum of 5, maximum of 8 characters

IP Address

 

IP address for Network Access

 

Note 1: The ATCA 5 slot shelf needs to be populated in the following order.

1st SDR Slot 3:

2nd SDR Slot 4:

3rd SDR Slot 5:

4th SDR Slot 1:

5th SDR Slot 2.

Slot 1 being at the bottom, Slot 5 at the top.