Base Station |
Information |
Notes | |
---|---|---|---|
BS location |
|
| |
ATCA rack identity |
|
| |
GPS timing reference |
|
Whether the system is required to be locked to a GPS timing reference. | |
SDR Blade (per Blade) |
|||
SDR Blade Slot x |
|
This needs to be provided for each SDR Blade. See Note 1 | |
Primary Master, Secondary Master or a Slave |
|
Whether the SDR is to be a Primary Master, Secondary Master or a Slave. This information will be mapped to the ATCA rack slot number by this procedure. | |
GPS management |
|
Whether the Primary Master blade or the Secondary Master blade manages the GPS module. | |
BSID |
|
A BSID is required for each SDR Blade. This should be in a format xxxxxx:xxxxxx where x is a decimal digit. | |
SCRT ID to Obsai port ID Mapping |
|
The mapping of SCRT ID to Obsai port ID on the SDR blade. | |
Network configuration
|
Network configuration information for the SDR blade. This shall include the following information for the front panel and the backplane. |
||
Traffic Port |
|
Defines whether traffic is via the front panel of the "SDR blade", "Primary Backplane" or "Secondary Backplane". | |
IP Address |
|
Should only be set if "Management IP Mode" is set to "Static IP Address" See below for "Management IP Mode" parameter. | |
Netmask |
|
Should only be set if "Management IP Mode" is set to "Static IP Address" See below for "Management IP Mode" parameter. | |
Default Gateway |
|
Should only be set if "Management IP Mode" is set to "Static IP Address" See below for "Management IP Mode" parameter. | |
Management VLAN |
|
Specified as either "Untagged" or "Tagged" | |
Management VLAN Tag |
|
Should only be set if "Management VLAN" is set to "Tagged" | |
Management IP Mode |
|
Specified as "Static IP Address" or "Obtain IP Address via DHCP" | |
Ethernet Mode |
|
Specified as "Autonegotiate" or "Fixed" | |
Ethernet Rate |
|
Need only be configured if "Ethernet Mode" is set to "Fixed". Specified as "10M" or "100M". | |
Ethernet Duplex |
|
Need only be configured if "Ethernet Mode" is set to "Fixed". Specified as "Full" or "Half" | |
SNMP Configuration |
This will allow events from the BS to arrive at the specified Netspan server. This will include the following information: |
||
Read Only Community |
|
This should be specified to the same value as in Netspan's Discovery Parameters. (Found under "Server" on Netspan's left hand panel). | |
Read Write Community |
|
This should be specified to the same value as in Netspan's Discovery Parameters. (Found under "Server" on Netspan's left hand panel). | |
SNMP Port Number : |
|
This should be specified to the same value as in Netspan's Discovery Parameters. (Found under "Server" on Netspan's left hand panel). | |
IP Address |
|
This specifies Netspan's IP address (Found under "Server Global Configuration" which is under "Server" on Netspan's left hand panel). | |
Community |
|
Normally specified to the same value as for "Read Only Community" | |
Port Number |
|
Normally specified to a value of 9023. | |
NTP Configuration |
|
This specifies a list of NTP servers. | |
Switch (per Switch) |
|||
Blade Traffic /Management |
Traffic |
Management |
Separate Ethernet management and traffic ports or an Ethernet port with combined management and user traffic. |
Switch Management
|
In Band |
Out of Band |
Switch Management in Network Ethernet (in band) or in separate Management Ethernet (out of band).
|
|
|
IP addresses for management | |
Shelf Manager |
|||
Shelf Address |
|
Up to 30 character string used to identify this shelf. | |
Password |
|
minimum of 5, maximum of 8 characters | |
IP Address |
|
IP address for Network Access |
Note 1: The ATCA 5 slot shelf needs to be populated in the following order.
1st SDR Slot 3:
2nd SDR Slot 4:
3rd SDR Slot 5:
4th SDR Slot 1:
5th SDR Slot 2.
Slot 1 being at the bottom, Slot 5 at the top.