Junction Box (USA And Canada only)

This instruction applies to USA and Canada only.

The main supply to the SDR is connected using a junction box as follows

To connect AC main supply to the SDR

  1. Fix a junction box in close proximity to the SDR.

 

  1. Run and fix a conduit from the main distribution board to the junction box.

  2. Strip sufficient cable sheath from the end of the SDR power cable to allow for the wire termination.

  3. Insert the cable from the SDR through the gland and terminate.

  4. Tighten the seal to create a watertight barrier for the SDR cable entry.

  5. Terminate the SDR supply cable as shown in the illustration above.

Connection

Color

Earth (Ground)

Green

Neutral (Cold)

White

Live (Hot)

Black

 

  1. Run a main supply cable from the main distribution board to the junction box through the conduit. This supply shall be protected on the distribution board by a 16A fast acting fuse or miniature circuit breaker.

  2. Terminate the main supply cable as shown in the illustration above.