48V Connectors |
300N.cm |
OBSAI Connectors |
100N.cm |
Each SCRT is provided with a 48 volt power cable terminated with a female connector at the SCRT end and a male connector at the other. The termination details for the SDR-micro are shown in the relevant installation manual.
Each SCRT is provided with a 48 volt power cable terminated with a female connector at the SCRT end and bare wires at the other. The termination details for the -48v supply are shown in the relevant installation manual.
Important
Note: The female connector attaches to the SCRT
and the male connector attaches
to the SDR-micro. It is important
that the power connector is attached at the correct end. See illustration
below or damage to the connector/equipment will result.
Power connector cable termination for SCRT end
When running cables care should be taken
not to exceed a force of 800N on the cable or connector. Do not kink cable
or bend over sharp edges.
Each SCRT is connected with an optical fibre cable, ready terminated with optical connectors. Unscrew the protective dust cap and screw the fibre optic cable in place. Only remove the cap prior to installation and never leave the optical interface open without a protection cap.
Tighten to 1Nm using a calibrated torque wrench. Never exceed 2Nm as the optical interface may be damaged causing excess losses
RF feeder connector: N-Type Female: Impedance: 50ohms: Minimum In-band Return Loss:15dB.
A screw terminal is provided on the SCRT for bonding the SCRT to a protective earth.