Function Tone
The short tone bursts that follow the High Level Guard Tone (HLGT). These bursts are mapped to functions in the station. For instance, setting the repeat mode, choosing a frequency, etc. Typically function tone is 40 ms in length. Dual function tone is needed if encryption is supported. MCC 7500 Dispatch Console does not support encrypted analog conventional stations, thus only single function tone is required.