General Properties Tab for MLC 8000 Analog Comparator Configuration in a Non IP Simulcast System

This section contains a table showing the fields on the General Properties Tab used for configuring MLC 8000 Analog Comparators in non IP simulcast systems. For each field, the field name, default value, range of values, and description are shown along with whether the field is editable.

In the following table, all fields are editable unless there is a note in the description column indicating otherwise.

General Properties Tab Fields for MLC 8000 Analog Comparators in Non IP Simulcast Systems
Field Default Value Range of Values Description
Device ID Blank 00001 to 65535 Decimal number which serves as a unique identifier for the MLC 8000 Analog Comparator device.
NoteYou cannot edit this field.
Device Name Blank 0 to 19 alphanumeric characters Name assigned to the MLC 8000 Analog Comparator device by the administrator.
NoteIf you modify this field, the MLC 8000 Analog Comparator is restarted to implement the new parameter value.
IP Address 0.0.0.0 As per System Configuration Plan ICD - IP Plan Specifies the device IP address of the MLC 8000 Analog Comparator unit.
NoteYou cannot edit this field.
Minimum Jitter Buffer (msec) 20 msec 10, 20, 30, 40, or 50 msec Minimum Jitter Buffer is used for outbound traffic from the MLC 8000 Analog Comparator for non IP simulcast systems.
NoteIf you modify this field, the MLC 8000 Analog Comparator is restarted to implement the new parameter value.
Version Name Blank Up to 31 alphanumeric characters Specifies the release version of the device.
NoteYou cannot edit this field.