Voting Operation Modes Tab for MLC 8000 Analog Comparator Configuration in a Non IP Simulcast System
This section contains a table showing the fields on the Voting Operation Modes Tab used for configuring MLC 8000 Analog Comparators in a non IP simulcast system. For each field, the field name, default value, range of values, and field description are provided.
In the following table, all fields are editable unless a note in the description column indicates otherwise.
Field | Default Value | Range of Values | Description |
---|---|---|---|
Voice Repeat Operation | Voice Repeat Operation Enabled | Voice Repeat Operation Disabled or Voice Repeat Operation Enabled | Specifies whether the MLC 8000 Analog Comparator works in repeat mode or not.
NoteIf you modify this field, the MLC 8000 Analog Comparator is restarted to implement the new parameter value.
|
Source-Based Priority | Console over Repeat | Console over Repeat or Repeat over Console | Specifies the signal priority based on the device that sourced the signal arriving at the MLC 8000 Analog Comparator port.
NoteIf you modify this field, the MLC 8000 Analog Comparator is restarted to implement the new parameter value.
|
TRC Regional Time | Infinite | 0 second to 100000 seconds, Infinite, increments of 1 second | While in TRC Transmitter Steering mode (from the Console Frequency Select), started when the dispatchers and radios have de-keyed. Canceled when audio is received from a dispatcher or radio within the selected region. If expires, the TRC Transmitter Steering mode is de-activated and Voted Transmitter Steering is applied. The TRC Regional Time is only valid when Transmitter Steering is enabled and the Voting Type is Regional Voting. |
TRC Command | No default | Repeater ON, Repeater OFF, Select Transmit Group, No Action | Select Transmit Group is only available when Transmitter Steeringis enabled. Note at least one TRC function must be No Action, then Select Transmit Group is used so TRC Transmitter Steering can be turned off from the Console. |