MLC 8000 Link Converter MOSCAD NFM I/O Monitoring Indications (Non IP Simulcast)

Legend:

Note
MLC 8000 Link Converter and MOSCAD NFM I/O Monitoring Indications (Non IP Simulcast).
For optimal reading convenience, hide the left pane.
Pin
  • I/O Wiring
  • Punch Block
SDM3000 Builder
# Name I/O Object Name "On" Message "Off" Message Description Legend Severity
1 5v Output AI EXS-xxxxxxxxxxx Present Not Present or VIP cable is disconnected EXS-xxxxxxxxxxx Unit presence major
3 VIP2 N/A N/A Not used
4 VIP3 Output DI L2V-xxxxxxxxxxx VGU links fail VGU link(s) OK L2V-xxxxxxxxxxx Cmprtr lnk fail major
5 VIP4 Output DI L2B-xxxxxxxxxxx BR links failed BR link(s) OK L2B-xxxxxxxxxxx Link to BR fail major
6 VIP5 N/A N/A Not used
7 VIP6 Input DO RST-xxxxxxxxxxx Device restart RST complete RST-xxxxxxxxxxx Restart device normal