MLC 8000 Analog Comparator and MOSCAD NFM I/O Monitoring Indications (IP Simulcast)

Legend:

Note
MLC 8000 Analog Comparator and MOSCAD NFM I/O Monitoring Indications (IP Simulcast).
For optimal reading convenience, hide the left pane.
Pin
  • I/O Wiring
  • Punch Block
SDM3000 Builder
# Name I/O Object Name "On" Message "Off" Message Description Legend Severity
1 5v Output AI EXS-xxxxxxxxxxx Present Not Present or VIP cable is disconnected EXS-xxxxxxxxxxx Unit presence critical
3 VIP2 Output DI GPN-xxxxxxxxxxx
  • Not Synch
  • (Location)
Location in synch GPN-xxxxxxxxxxx Synch with Location critical
4 VIP3 Output DI L2B-xxxxxxxxxxx BR links failed BR links OK L2B-xxxxxxxxxxx Link to BR fail major
5 VIP4 Output DI LDL-xxxxxxxxxxx Bad link delay or console port's ALC is out of dynamic range AGUs in synch and console port's ALC is within dynamic range LDL-xxxxxxxxxxx Link delay or console port's ALC dynamic range major
6 VIP5 N/A N/A Not Used
7 VIP6 Input DO RST-xxxxxxxxxxx Device restart RST complete RST-xxxxxxxxxxx Restart device normal