MLC 8000 Link Converter and MOSCAD NFM I/O Monitoring Indications (IP Simulcast)

Legend:

Note
MLC 8000 Link Converter and MOSCAD NFM I/O Monitoring Indications (IP Simulcast).
For optimal reading convenience, hide the left pane.
Pin
  • I/O Wiring
  • Punch Block
SDM3000 Builder
# Name I/O Object Name "On" Message "Off" Message Description Legend Severity
1 5v Output AI EXS-xxxxxxxxxxx Present Not Present or VIP cable is disconnected EXS-xxxxxxxxxxx Unit presence major
3 VIP2 Output DI GPN-xxxxxxxxxxx Not Synch(GPS) GPS in synch GPN-xxxxxxxxxxx Synch with GPS minor
4 VIP3 Output DI L2V-xxxxxxxxxxx VGU link failed VGU link OK L2V-xxxxxxxxxxx Cmprtr lnk fail major
5 VIP4 Output DI L2B-xxxxxxxxxxx BR link failed BR links OK L2B-xxxxxxxxxxx Link to BR fail major
6 VIP5 Output DI BLT-xxxxxxxxxxx Bad Launch time Launch time OK BLT-xxxxxxxxxxx Bad launch time minor
7 VIP6 Input DO RST-xxxxxxxxxxx Device restart RST complete RST-xxxxxxxxxxx Restart device normal