Slider to Tone Signal Power Range
This section provides a table showing the slider value to be associated with a particular measured tone signal power range.
Use this table to determine the appropriate slider value for a particular measured input signal power range. For information on calculating power, see Performing Calibration for an MLC 8000 Analog Comparator for a TRC Console.
Measured Input Signal Power Range (dBm) | Slider Value (Steps) |
---|---|
12.0 to 10.5 | 1 |
10.5 to 9.0 | 2 |
9.0 to 7.5 | 3 |
7.5 to 6.0 | 4 |
6.0 to 4.5 | 5 |
4.5 to 3.0 | 6 |
3.0 to 1.5 | 7 |
1.5 to 0.0 | 8 |
0.0 to -1.5 | 9 |
-1.5 to -3.0 | 10 |
-3.0 to -4.5 | 11 |
-4.5 to -6.0 | 12 |
-6.0 to -7.5 | 13 |
-7.5 to -9.0 | 14 |
-9.0 to -10.5 | 15 |
-10.5 to -12.0 | 16 |
-12.0 to -13.5 | 17 |
-13.5 to -15.0 | 18 |
-15.0 to -16.5 | 19 |
-16.5 to -18.0 | 20 |
-18.0 to -19.5 | 21 |
-19.5 to -21.0 | 22 |
-21.0 to -22.5 | 23 |
-22.5 to -24.0 | 24 |
-24.0 to -25.0 | 25 |