4W MLC 8000 (Analog Comparator) to Site Gateway (Conventional Channel Interface) Cable

This section provides information for connecting the MLC 8000 RJ45 cable to a Site Gateway (Conventional Channel Interface).

4W MLC 8000 (Analog Comparator) to Site Gateway (CCGW) RJ45-to-RJ45 Cable
4W MLC 8000 (Analog Comparator) to Site Gateway (CCGW) Cable
End A,     End B,  
MLC 8000 (Analog Comparator)   Site Gateway (CCGW)
Pin No. Signal Wire Color Pin No. Signal
1 Audio Out+ White/Orange 1 TIP2
2 Audio Out- Orange 2 RING2
3 Audio In + White/Blue 5 TIP1
4 Audio In - Blue 4 RING1
5* Channel Active White/Green Not connected Not connected
6 PTT from Console Brown Not connected Not connected
7 5V Green Not connected Not connected
8 VGND White/Brown Not connected Not connected
Important*If you connect the CCGW (Site Gateway) to a console that uses Channel Active indication (or both Channel Active indication and VOX). The connections should be as shown in MLC 8000 Analog Comparator to Site Gateway (CCGW) with CTI or CTI GPIO to CCGW.
NoteCurrently PTT signal in the console is not in use. This is PIN 6 in End A. This will be implemented in a future release.