Associating Base Radio Receivers (Region) to a Base Radio Receiver in the Voted (Receiver) Transmitter Steering Table
This procedure provides the details for associating the BR receivers for a region using the Regional Voting type on the Analog Vote tab of the MLC 8000 Comparator.
Prerequisites:
- The MLC 8000 Configuration Tool is operational. See procedure Opening the MLC 8000 Configuration Tool.
- The channel cluster for which you wish to update the transmitter steering table is open and displayed on the MLC 8000 Configuration Tool main screen.
- In the Analog Vote tab of the MLC 8000 Analog Comparator configuration screen, the Transmitter Steering parameter is selected and the Voting Type is set to Regional Voting. See Configuring an MLC 8000 Analog Comparator for an IP Simulcast System and Configuring an MLC 8000 Analog Comparator for a Non IP Simulcast System.
- A base radio list has already been assigned to the MLC 8000 Analog Comparator (VGU).
NoteThis procedure should be repeated until all base radio receivers have the desired receivers associated. At the end of the association process, the default association for a base radio receiver is
All BRs (all base radio transmitters). At the table configuration, a
Console entry is available, similar to the base radio receiver, which enables the Console default transmitter and receiver steering associations.
When and where to use:
Use this procedure to:- Associate base radio receivers (a region) to a base radio receiver of an MLC 8000 Analog Comparator.
- View a Voted (receiver) transmitters and receivers list. That is, the transmit and receive region of the steering table. For viewing, use steps 1 and 2 only.
Procedure:
- From the channel cluster tree displayed on the main menu of the MLC 8000 Configuration Tool, right-click the MLC 8000 Analog Comparator (VGU) for which you want to update the steering table.
- Select Update Voted Transmitter Steering Table.
- In the right column, select the check box of the base radio you want to associate with the receivers. The Select All check box is available in the lower-left corner.
- Click Associate Receive BRs.
A list of unassociated (to the previously selected receiver) base radio receivers appear on the left side and the list of associated receivers is on the right side.The Receive BR Selection for Regional Voting dialog box appears.
- From the (Subsite) Receive BR list, select all base radio receivers that you wish to associate using the Ctrl key for multiple selections. Click Add.
- If necessary, from the Selected (Subsite) Receive BR list, select the base radio receivers that you want to unassociate using the Ctrl key for multiple selections. Click Remove.
A Remove Alloption is available to unassociate all receivers with the previously selected base radio receiver.
- Click OK.
NoteRepeat steps 3 through 8 for the rest of the receivers to populate the transmitter steering table. In the case where a base radio receiver was associated with an empty list (no receivers associated), the MLC 8000 Analog Comparator (VGU) automatically associates the base radio receiver to itself and an empty list is not possible. The automatic update appears after the next step.
- Click Apply.
The MLC 8000 Analog Comparator Voted (Receiver) transmitter steering table updates and the window closes.